Tyvek / Tyvek® IsoClean®

IC 193 B WH DS

Tyvek® IsoClean®

DuPont™ Tyvek® IsoClean® hooded coverall, model IC 193 B WH DS. Clean-processed and gamma-sterilized. Bound internal seams. Integrated overboots with a slip retardant Gripper™ sole. The hood fits a medical mask and has attached ties. Tunnelled elastication at wrists. Elasticated waist at back. Tyvek® covered elasticated thumb loops. Zipper closure. Storm flap. Aseptically folded. CE-certified. White.

 
 
 
Hover over image to zoom

CAT III

T5

T6

EN 1073-2

EN 14126

Option DS

ISO-11137

Name Description
Full Part Number IC193BWHDS
Fabric/Materials TYVEK® ISOCLEAN®
Design Hooded coverall with integrated overboots
Seam Bound
Color White
Sizes XS, SM, MD, LG, XL, 2X, 3X, 4X, 5X, 6X, 7X
Quantity/Box 20 per box, individually double packed. 2 polyethylene liners. Cardboard box.

FEATURES & PRODUCT DETAILS

DuPont™ Tyvek® IsoClean® hooded coverall, IC 193 B WH DS. Available in sizes XS to 7X. Clean-processed and gamma-sterilized. Bound internal seams. Integrated overboots with a slip retardant Gripper™ sole. The hood fits a medical mask and has attached ties. Elasticated waist at back for good fit. Tyvek® covered elasticated thumb loops. Tunnelled elastication at wrists. Front zipper closure. Storm flap.Tyvek® IsoClean® delivers an ideal balance of protection, durability and comfort. Made of high density polyethylene using a patented flash spinning process. Tyvek® IsoClean® provides an inherent barrier to particles, microorganisms and non-hazardous water-based light liquid splash. Tyvek® IsoClean® is also breathable and low linting.All DuPont™ Tyvek® IsoClean® clean-processed and sterile garments (option code DS) are packed in a dual barrier packaging system, consisting of an inner and outer easy tear cleanroom bag. The packaging system serves as a key element for contamination risk reduction when transferring apparel into clean areas.Garments and accessories made of clean-processed and sterile Tyvek® IsoClean® are typically used in cleanrooms within the biotech, pharmaceutical, medical device manufacturing, food processing, cosmetics industry as well as in other critical or controlled environments.

  • Certified according to Regulation (EU) 2016/425.
  • Clean-processed and sterilized by gamma-irradiation to SAL of 10-6 (ISO 11137-1)
  • Clean-processed and sterilised by gamma-irradiation to SAL of 10-6 (ISO 11137-1)
  • Suitable for use in GMP class A/B (ISO Class 5) clean rooms*
  • Full traceability on all sterilized apparel with certificates of sterility available
  • Suitable for use in GMP class A/B (ISO Class 5) clean rooms*
  • Hood and integrated boots
  • Tyvek® IsoClean provides an inherent barrier to particles, microorganisms and non-hazardous water-based light liquid splash
  • Tyvek® IsoClean is also breathable and low linting. Aseptically folded
  • Chemical protective clothing, Category III, Type 5-B and 6-B. (1956)
  • EN 14126 (barrier to infective agents), EN 1073-2 (protection against radioactive contamination)..

Fabric & Permeation/Penetration Data

Physical Properties

Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.

Property Test Method Typical Result EN
Abrasion Resistance 7 EN 530 Method 2 >10 cycles 1/6 1
Basis Weight DIN EN ISO 536 45 g/m2 N/A
Flex Cracking Resistance 7 EN ISO 7854 Method B >100000 cycles 6/6 1
Puncture Resistance EN 863 >5 N 1/6 1
Resistance to water penetration AATCC 127 >7 kPa N/A
Tensile Strength (MD) DIN EN ISO 13934-1 >30 N 1/6 1
Tensile Strength (XD) DIN EN ISO 13934-1 >30 N 1/6 1
Trapezoidal Tear Resistance (MD) EN ISO 9073-4 >10 N 1/6 1
Trapezoidal Tear Resistance (XD) EN ISO 9073-4 >10 N 1/6 1
  •  According to EN 14325
  •  According to EN 14126
  •  According to EN 1073-2
  •  According to EN 14116
  •   According to EN 11612
  •  Front Tyvek ® / Back
  •  Based on test according to ASTM D-572
  •  See Instructions for Use for further information, limitations and warnings
  •  Larger than
  •  Smaller than
  •  Smaller than or equal to
  •  Not Applicable
  •  Standard Deviation

COMFORT

BIOLOGICAL BARRIER

PENETRATION AND REPELLENCY

CLEANLINESS

GARMENT PERFORMANCE

WARNING

PERMEATION DATA

To access secured content from DuPont Please Sign In or Sign Up below