IC 270 B WH MS
Tyvek® IsoClean®
DuPont™ Tyvek® IsoClean® labcoat with bound neck, model IC 270 B WH MS. Bound internal seams. Tunnelled at wrists. Front snap closure. Clean-processed and gamma-sterilized. Aseptically folded. White.
The following information must be read and accepted by the user before proceeding.
The DuPont™ SafeSPEC™ Product Selector Tools - Hazard, Industry, Guide, My Scenarios and Double-check- are intended to assist in choosing protective clothing for particular applications and does not replace the judgment of a qualified safety professional or industrial hygienist. Additional personal protective equipment, such as such as but not limited to: respiratory, eye, head, foot, and hand protection, may be required.
Supplying the proper hazard/chemical and exposure information for your hazard scenario is criticalin order to obtain an accurate recommendation. Inaccurate information could result in an improper recommendation. To ensure that the hazard/chemical information is accurate, consult the MSDS (Material Safety Data Sheet) supplied with the chemical. DuPont DISCLAIMS ANY RESPONSIBILITY OR LIABILITY FOR SUITS SELECTED USING these PRODUCT SELECTOR TOOLS, BASED ON ANY INCOMPLETE, INACCURATE, OR MISLEADING INFORMATION PROVIDED BY THE USER. There are other factors involved which could affect the final PPE (Personal Protective Equipment) decision and may not be considered in these Product Selector Tools. SafeSPEC™ Product Selector Tools provides information on DuPont suit styles for particular applications. The final decision on suit selection is the responsibility of the safety professional and end-user.
There are uses, environments and chemicals for which any garment will be unsuitable. It is the responsibility of the user to review available data and verify that the garment selected is appropriate for the intended use and meets all specified government and industry standards.
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 1 of 3
You may enter from one to five chemicals or other hazards that may be present in your working environment. Our tool will find the best product match for the combined hazards. Enter a single chemical or hazard if you wish to find the best possible product match for that one hazard.
Chemical or Other Hazard Name
or
CAS Number
Chemical Details | CAS | Actions |
---|
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 2 of 3
The table below shows the Normalized Breakthrough times of fabrics for the hazards selected. (Testing Details) You can find specific garments that protect against these hazards by clicking the 'Next' button below.
Done
Done
Done
TYVEK | TYCHEM | GLOVES |
---|
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 3 of 3
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
step3of3
Hazard | Fabric/Materials | Seam | Design |
---|
Hazard | Fabric/Materials | Seam | Design |
---|
Name | Description |
---|---|
Full Part Number | IC270BWHMS |
Fabric/Materials | Tyvek® IsoClean® MS |
Design | Labcoat with snap closure |
Seam | Bound |
Color | White |
Sizes | SM, MD, LG, XL, 2X, 3X, 4X |
Quantity/Box | 30 per box, individually packed. Subgrouped by 5 in an outer bag. 2 polyethylene liners. Cardboard box. |
DuPont™ Tyvek® IsoClean® labcoat with bound neck, IC 270 B WH MS. Available and in sizes SM to 4X. Clean-processed and gamma-sterilized. Bound internal seams. Tunnelled elastication at wrists. Front snap closure for easy donning and doffing.Tyvek® IsoClean® delivers an ideal balance of protection, durability and comfort. Made of high density polyethylene using a patented flash spinning process. Tyvek® IsoClean® provides an inherent barrier to particles, microorganisms and non-hazardous water-based light liquid splash. Tyvek® IsoClean® is also breathable and low linting.Tyvek® IsoClean® (option codes DS and MS) garments and accessories have been clean-processed to maximize cleanliness and have been sterilized by gamma- irradiation. They are folded to aid aseptic donning and packaged in an ISO class 4 cleanroom. All DuPont™ Tyvek® IsoClean® clean-processed and sterile accessories (option code MS) are packed in a dual barrier packaging system, consisting of an inner and outer easy tear cleanroom bag. The packaging system serves as a key element for contamination risk reduction when transferring apparel into clean areas. The accessories are individually packed and grouped together in an outer bag.
Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.
Property | Test Method | Typical Result | EN |
---|---|---|---|
Abrasion Resistance 7 | EN 530 Method 2 | >10 cycles | N/A |
Basis Weight | DIN EN ISO 536 | 45 g/m2 | N/A |
Flex Cracking Resistance 7 | EN ISO 7854 Method B | >100000 cycles | N/A |
Puncture Resistance | EN 863 | >5 N | N/A |
Resistance to water penetration | DIN EN 20811 | 8 kPa | N/A |
Tensile Strength (MD) | DIN EN ISO 13934-1 | >30 N | N/A |
Tensile Strength (XD) | DIN EN ISO 13934-1 | >30 N | N/A |
Trapezoidal Tear Resistance (MD) | EN ISO 9073-4 | >10 N | N/A |
Trapezoidal Tear Resistance (XD) | EN ISO 9073-4 | >10 N | N/A |