TFCHA5TOR00
Tychem® 6000 F
DuPont™ Tychem® 6000 F Orange. Hooded coverall. Stitched and over-taped seams. Thumb loops. Elastication at wrists, ankles, face and waist. Self-adhesive double zipper flap and chin flap. Orange.
HIGHER than what is listed in the "Search Hazards" box. What should I do?
If the concentration of your hazard is HIGHER than the hazard concentration listed in the hazard search box, you can NOT use the data for the lower concentration hazard. This data will not give you an accurate assessment of suitable garments. Please Contact Us for assistance.
HIGHER than what is listed in the "Search Hazards" box. What should I do?
If the temperature of your hazard is HIGHER than the hazard listed in the hazard search box, you can NOT use the data for the lower temperature hazard. Chemical hazards become more aggressive with increasing temperatures. Selecting a lower temperature chemical hazard will not give you an accurate assessment of suitable garments.
PLEASE NOTE: DuPont garments do not provide adequate insulation to protect the wearer's skin against prolonged exposures to high temperature chemical hazards. Depending on the temperature of the chemical hazard and the duration of exposure, the wearer could be subjected to a thermal burn.
Unless otherwise stated, DuPont tests chemical hazards per ASTM F739 at ambient temperatures (approximately 72-81°F ; 22-27°C).
LOWER than what is listed in the "Search hazards" box. What should I do?
If the temperature of your hazard is LOWER than the hazard listed in the hazard search box, go ahead and select the higher temperature hazard as long as the physical phase (solid, liquid or gas/vapor) is the same. Because chemical hazards become more aggressive with increasing temperatures, selecting a higher temperature chemical hazard will lead to a more conservative result.
PLEASE NOTE: DuPont garments do not provide adequate insulation to protect the wearer's skin against prolonged exposures to cold temperature hazards. Depending on the temperature of the chemical and the duration of exposure, the wearer could be subjected to frostbite. In addition, at temperatures below -13°F (-25°C), some DuPont fabrics could lose flexibility.
Unless otherwise stated, DuPont tests chemical hazards per ASTM F739 at ambient temperatures (approximately 72-81°F ; 22-27°C).
A Steady State Permeation Rate is a constant permeation rate after reaching an equilibrium. Steady State Permeation Rate is not necessarily reached within the normal test duration of 480 minutes for each chemical-fabric combination.
The permeation data provides you information on the barrier a protective clothing material offers against a hazardous chemical. Permeation is determined by measuring the breakthrough time and the subsequent permeation rate of the chemical through the material. Permeation rate is defined as the speed at which the hazardous chemical permeates through the test material. Breakthrough time is defined as actual and normalised breakthrough time. The actual breakthrough time is the time elapsed between initial contact of the chemical with the outside surface of the material and the detection of the chemical at the inside surface by the analytical device. An actual breakthrough time of > 480 minutes and a permeation rate of and (not detected) does not mean breakthrough has not occurred. It means that permeation was not detected after an observation time of eight hours. Permeation may have occurred, but at less than the minimum detectable permeation rate. Since actual breakthrough times depend on the sensitivity of the analytical device, the concept of normalised breakthrough times is used. The normalised breakthrough time is defined as the elapsed time between initial contact of the chemical with the outside surface of the material and the time at which the chemical is detected at the inside surface of the material at a permeation rate of 1 cm in (according to EN/ISO 6529, EN 369 or EN 374-3) and 0.1 cm in (according to EN/ISO 6529/ASTM F739). A normalised breakthrough time of > 480 minutes means that the average permeation rate has never reached the defined rate (0.1 min or 1.0 miin) according to the referred norm. However, the chemical may have actually broken through. Attention: The classification of permeation data according to EN ISO 6529 can refer to normalised breakthrough time at 0.1 min or 1.0 min. Therefore, we strongly recommend you verifying at which normalised breakthrough time any performance classification ( e.g. class 1 to 6) is based.
Tychem® C and Tychem® F garment seams open at 98 Tychem® fabrics are not a thermal barrier, so to avoid injury, ensure correct undergarments are worn.
A Cumulative Permeation Mass is the total amount (mass) of chemical that permeates the fabrics during a certain time.
TYCHEM® styles retain their flexibility down to 0
Tychem® chemical protective suits are used to protect people from hazards and processes from contamination by people in a wide range of applications, such as: Chemical industry, pharmaceutical industry, automotive, food industry, agrochemical handling, transportation, petrochemical industry, industrial cleaning and maintenance, cleanroom applications, emergency response and military. Tychem® C - protection against many concentrated inorganic chemicals, biological hazards and ultra fine particles. Tychem® F protection against various organic chemicals and highly concentrated inorganic, biological hazards, ultra fine particles and oil. Tychem® C2 - protection against many concentrated inorganic chemicals, biological hazards and ultra fine particles and offers improved tightness level at a higher mechanical strength. Tychem® F2 - protection against various organic chemicals and highly concentrated inorganic, biological hazards, ultra fine particles and offers improved tightness level at a higher mechanical strength.
A Cumulative Permeation Time is a time which is required to reach a a total quantity of a chemical per squaremeter. Safespec report the time which is required t acumulate a mass of 150 m time150).
A Minimum Detection Permeation Rate (MDPR) is the lowest measurable rate for a measurement system, The MDPR can vary depending on the sensivity of the analytical device for a given test chemical.
The permeation resistance of a fabric is classified according to EN 14325 into 6 level of performance (classes) based on the time which is required to reach a normalized breakthrough time of 1.0 min (BT0.1) when tested according to EN 374-3 or ISO 6529. Class 6 is reached when the BT 1.0 is larger than 480 minutes. Class 5 is reached when the BT 1.0 is larger than 240 minutes. Class 4 is reached when the BT 1.0 is larger than 120 minutes. Class 3 is reached when the BT 1.0 is larger than 60 minutes. Class 2 is reached when the BT 1.0 is larger than 30 minutes. Class 1 is reached when the BT 1.0 is larger than 10 minutes. This classification can simplify the Use of Permeation data.
Normalised breakthrough detection time is the elapsed time between the initial contact of the chemical with the outside surface of the fabric and the time at which the chemical is detected at the inside surface of the fabric at a certain permeation rate. The most common normalized detection rates are 0.1 min (BT0.1) and 1.0 min (BT1.0). A normalized detection rate of 0.1 min is used for measurements according to EN ISO 6529 or ASTM F739. A normalized detection rate of 1.0 min is used for measurements according to ISO 6529, EN 369 or EN 374-3. A normalised breakthrough time of > 480 minutes means that the average permeation rate has never reached the defined rate (0.1 min or 1.0 min) according to the referred norm. Actual breakthrough time is the time elapsed between initial contact of the chemical with the outside surface of the fabric and the detection of the chemical at the inside surface by the analytical device (minimum detection permeation rate, MDPR). An actual breakthrough time of > 480 minutes does not mean breakthrough has not occurred. It means that permeation was not detected after an observation of eight hours. Permeation may have occurred, but at a rate less than the minimum detectable permeation rate of the analytical device.
It depends on the specific chemical substance, toxicity of the substrate, concentration, fabric barrier performance, garment area contaminated, temperature, pressure of substances when reaching garment surface and protective undergarment. By consulting the permeation data, based on the actual breakthrough time, you can already ascertain whether a constituent fabric offers a barrier for the duration of the task. Where actual breakthrough times are less than the duration of the task, caution is needed.
Permeation measurements can be conducted for liquid and gaseous chemicals for which an analytical methode with a reasonable detection limit is available. Solids can be solved in a solvent. The fabric needs to perform as a barrier to this solvent. The chemical shall not be a risk for the (e.g.
Permeation tests, by comparison, are better suited for testing hazardous liquids and vapors. It is the test method of choice for Tychem® fabrics. There are many critical factors that influence permeation: the challenge chemical (i.e. concentration, temperature, surface tension, the size of the molecules, functional groups, etc.), the make-up of the barrier material, the exposure time and several physical factors like ambient temperature and pressure, just to name a few. Because there are so many variables, DuPont has performed permeation tests on hundreds of chemicals against our Tychem® fabrics.
Warefare agents are tested according to MIL_STD_282 at 22r according to FINABEL 0.7 at 37. Due to the anaytical methods which is used in these standards the result of the measurements are proported at actual breakthrough times only.
[Garment] has been tested according to EN 14126 (Protective clothing- Performance requirements and tests methods for protective clothing against infective agents) and passed the tests in the highest performance classes. [Garment] can be used for inspection and dry particulate and liquid exposures. We suggest this [Garment] for handling biological agents which are are classified into risk group 3 according to the Council Directive 90/679/EEC. Group 3 biological agents means one that can cause severe human disease and present a serious hazard to workers; it may present a risk of spreading to the community, but there is usually prophylaxis and treatrment available. Examples for Bacillus anthracis/ Mycobacterium tuberculosis/ Yersinia pestis/ Hepatitis B virus/ Monkey pox virus/ Hepatitis B virus/ HIV virus/ Monkeypox virus/ Dengue virus/ Groupbiological agents can be handled as well with [Garmt]. The choice betweeen the garments depends on the desinfectant which is used.
TYCHEM® styles are not air - or water vapour permeable due to their material structure. The work place risk assessment should evaluate how long a wearer can work in a non-breathable suit. The environmental temperature, extent of the physical work, and physical health of the wearer should be considered. Frequent breaks and liquid refreshment should be taken into consideration.
Chemical protective clothing can interfere with the natural regulation of body temperature. This can lead to a rise in core body temperature and heat stress. Implementing a conservative work/rest schedule or using a cooling system like the DuPont™ Cool-Guard® vest may be effective in reducing heat stress. (Note: Do not wear cooling vests in potentially flammable or explosive environments.)
Be aware of the symptoms and treatment of heat stress. If you or your co-workers have symptoms of heat stress such as nausea, dizziness, high heart rates, or excessive heat build-up, leave the work area immediately and remove the ensemble as quickly as possible after decontamination and seek professional care.
The maximum length of time the chemical protective clothing can be worn depends on variables such as the air supply, ambient conditions, climate inside the ensemble, physical and psychological conditions of the wearer, work rate and work load. The TLV® pocket guide from the American Conference of Governmental Industrial Hygienists (ACGIH, Cincinnati) provides corrected heat stress limits for some garments. Similar information is available on the federal OSHA web site (www.OSHA.gov). The WBGT correction factor for chemical protective garments is at least 10°C or higher for chemical garments made of impervious films (such as Tychem® garments) and covering the entire body (hooded coverall or encapsulating designs). For Tyvek® coveralls, the WBGT correction factor is 2°C with a hood and 1°C without a hood.
Ideally a second person dressed in a chemical protective suit and other appropriate personal protective equipment provides assistance. To avoid a contamination while undressing the following order is recommended: If the garment is heavily contaminated it recommended to wet it in case of dust or to shower in case of liquid Clean the outer gloves arm parts and zipper area of the garment by using wipes Remove the outer glove while keeping on the inner glove Open the zipper carefully Remove the garment turning it inside out and pull it down to knees. Pull your feet out of the garment carefully Pull the garment together inside out - so the garment can be disposed of If wearing one, remove the mask Remove the inner glove
A proper dressing is a must for proper protection. There are a couple of steps to be considered : Check if the place of dressing is contaminant free Check the garment, check if type and size are appropriate, if the zipper is working and if the clothing material and seams are defect free Check compatibility of other Personal Protective Equipment (PPE) with protective suit selected as well as their functionality Decide whether normal working clothing or special underwear shall be worn under the garment Take off your shoesFirst enter the garment with your feet then the arms and pull it over your back Close the zipper up to chest high Put on safety boots Pull the garment leg over the boot If a mask is required for the considered task one shall put it on at this stage following the instructions given by the mask manufacturer Once the mask is put on, the hood is put on making sure that it fits tightly to the mask. Ideally a second person controls the tightness around the mask. If no second person is available it recommended to do the check with a mirror. Close the zipper as far as possible and make sure that the zipper flap covers the entire zipper. Put on the gloves (ideally inner and outer glove), if only one glove is used put the gauntlets below the sleeves. For additional protection the hood can be taped to the mask and the gloves to the sleeves. Furthermore it is recommended to tape the zipper flap.
LOWER than what is listed in the "Search Hazards" box. What should I do?
If the temperature of your hazard is LOWER than the hazard listed in the hazard search box, go ahead and select the higher temperature hazard as long as the physical phase (solid, liquid or gas/vapor) is the same. Because chemical hazards become more aggressive with increasing temperatures, selecting a higher temperature chemical hazard will lead to a more conservative result.
PLEASE NOTE: DuPont garments do not provide adequate insulation to protect the wearer's skin against prolonged exposures to cold temperature hazards. Depending on the temperature of the chemical and the duration of exposure, the wearer could be subjected to frostbite. In addition, at temperatures below -13°F (-25°C), some DuPont fabrics could lose flexibility.
Unless otherwise stated, DuPont tests chemical hazards per ASTM F739 at ambient temperatures (approximately 72-81°F ; 22-27°C).
Tychem® garments can be worn in ambient temperatures of -13°F (-25°C) to 120°F (49°C).
In colder environments, Tychem® garments can become stiff. If cold enough, the fabric may even become brittle. Please be aware that the heat stress of the wearer becomes a greater concern in higher ambient temperatures. At higher temperatures, chemical hazards can become more aggressive. Breakthrough times and permeation rates may change at higher temperatures. The published permeation data per ASTM F739 is performed at ambient temperatures (approximately 72-81° F ; 22-27° C).
Caution: Tychem® fabrics offer little or no thermal insulation to protect the wearer's skin from prolonged exposure to hot or cold.
When working in explosive environments it is recommended to first control the relative humidity since in extremely dry environments with a relative humidity below 25%, the antistatic finish on the garments may no longer function. The chemical protective suit must be correctly and continuously grounded via electrostatic dissipative shoes, floor and / or grounding cable. If the wearer of an antistatically treated garment is not connected to a grounded surface, the wearer/garment might remain charged.
The following typical mistakes that can happen when working with protective clothing have been reported to us: Opening of garment or mask while working in the risk zone. Interrupting the task and leaving the dangerous zone with contaminated garment and moving to other zones like offices. Carelessness of wearers with regard to hot surfaces, sparks or sharp edges. Employees with a passive role in the dangerous zone do often not wear protective clothing. No or false grounding of garments due to insufficient knowledge or underestimation of risk of electrostatic charging. Under protection: wrong fabric selection or garment tightness level for the hazard. Loss of protection if the suit becomes abraded or damaged and is not changed.
The size of the chemical protective suit selected is very important since proper fit is part of proper protection. Furthermore, a good fit ensures a protective suit is comfortable and avoids extra heat up which can be caused by too big suits. By poorly fitting garments either too small or too large you have an increased risk of tearing the garment and of being restricted in your movements or getting caught in machinery, which can adversely affect your ability to carry out your work safely.
Generally it is up to the wearer to decide on his/her personal underwear. For higher comfort we recommend the following: wear at least one layer of underwear under the chemical protective suit select underwear with long arms and legs underwear made from traditional fabric such as blended woven structures underwear made from high-performance fibres
In terms of chemical protective clothing, penetration is the passage of a chemical through a pore or opening in the barrier material. Permeation is the absorption, diffusion and desorption of a chemical through the barrier material at the molecular level.
Resistance to penetration by liquids is a process in which a chemical moves through pores, seams, apertures or essential openings in a material or finished item of a clothing. Repellency is the ability of a fabric to shed liquid that is applied to the surface of a fabric. Penetration and repellency is measured according to ISO 6530. This test is know a the "gutter-test". Reference chemicals for penetration and repellency testing are: 30 % Sulphuric acis, 10 & Sodium Hydroxide, o-Xylene, Butan-1-ol. Chemical protective clothing, Category III, Typ 6 requires a liquid repellency level of 3 for at least one of the four chemicals and a resistance to penetration at a performance level of at least 2 for one of the 4 chemicals. The peformance level for Penetration and Repellency is listed in the Instruction for Use for the specific garment and in SafeSPEC(TM) under Data/Penetration and Repellency. Measuring the resistance to penetration and repellency is a fabric test and only applicable for garments. The test is not required for the Certfication of Partial Body Protection.
Permeation measurements acc. to EN ISO 6529 (method A and B) can be reported at a normalized permeation rate at 0.1 min and/or 1.0 min. Measurements are conducted at 23. Permeation measurements acc. to ASTM F-739 are reported at a normalized permeation rate at 0.1 min. Measurements are conducted at 27.This norm is mainly used in the USA. Permeation measurements acc. to EN 374-3 are reported at a normalized permeation rate at 1.0 min. Measurement is conducted at 23. This norm is mainly used in the glove industry. EN 369 has been supersedes by EN ISO 6529:2001. Measurement which have been conducted to these norms are comparable due the use of normalized breakthrough detection times.
Permeation is the process by which a potentially hazardous chemical moves through a material on a molecular level. This process involves the following steps: 1. Sorption of molecules of liquid onto the contracted (outside) surface of the fabric. 2. Diffusion of the sorbed molecules across the fabric. 3. Desorption of the molecules from the opposite (inside) surface of the fabric. Permeation measurements are conducted to the following norms EN ISO 6529 (method A and B), ASTM F-739 or EN 374-3. For these methods a two-chambered test cell is used. The test specimen is positioned between the two sections of the cell. On the challenge side of the test cell the outside fabric surface is exposed continuously to the challenge chemical. The sampling side of the test cell is analytically monitored. The standard test duration is 480 minutes. Permeation measurements are conducted at room temperature and at at ambiant pressure (if not stated otherwise). EN ISO 6529 Methode A describes measurements o liquid chemicals with continous contact. EN ISO 6529 Methode B describes measurements of gaseous chemicals with continuous contact. The rest result of a peremation measurement is reported as a breakthrough time in minutes at a normalized permeation rate (BT0.1, BT1.0) or as a Class according to EN 14325. testing solid chemicals,
In general, garments must be correctly and continuously grounded by contact with electrostatic dissipative shoes, floor and/or grounding cable to the antistatic treated side of the garment. If the wearer of an antistatically treated garment is not connected to a grounded surface, the wearer/garment will remain charged. It also important to consider that electrostatic charges may also build up on ancillary equipment such as breathing apparatus and other devices. Therefore those must be separately grounded when worn in conjunction with a garment. Attention must be paid to the local humidity levels since in dry environments with a relative humidity below 25%, the antistatic finish may no longer function effectively. Garments with attached socks cannot be grounded via the shoes.
Tyvek® 800, Tychem® C, Tychem® C2, Tychem® 4000, Tychem® F and Tychem® F2 are antistatically treated on the inside surface only. Both materials meet surface resistivity criteria (according to EN 1149-1) to avoid incendiary discharge). Below 25% relative humidity of air the antistatic treatment may lose its dissipative properties. Tychem® TK. Has no antistatic treatment
When selecting protective clothing, DuPont recommends taking four steps to ensure an appropriate selection and successful implementation. Those steps are: 1. Risk assessment: Before searching for protective clothing, it is recommended to do a detailed assessment of the nature of the hazard, the type of exposure and the working environment. 2. Defining the appropriate garment type: Once a risk assessment has been made the appropriate garment type can be defined. 3. Research: Since there a variety of limited-use protective clothing available in the market one should consider certain performance criteria for the garment selection process, such as for example, protection, durability, comfort, quality, compatibility with other personal Protective equipment, environmental compatibility and value for money. Information on type certification, barrier performance and fabric physical properties can be gained from the use instructions supplied by the manufacturer while information on other properties, for example, user friendliness, protection performance in real applications amongst others can only be gained in a wear trial. 4. Testing for success: After having selected a Tyvek® chemical suit matching the analysed requirements it is recommended to carry out a wear trial under real working conditions to gain feedback from the employees. Furthermore, the employees feel integrated in the garment choice which may result in less acceptance problems when implementing the selected garment.
In the USA, OSHA 29CFR1910.132 states that it is the responsibility of the employer to:
The following information must be read and accepted by the user before proceeding.
The DuPont™ SafeSPEC™ Product Selector Tools - Hazard, Industry, Guide, My Scenarios and Double-check- are intended to assist in choosing protective clothing for particular applications and does not replace the judgment of a qualified safety professional or industrial hygienist. Additional personal protective equipment, such as such as but not limited to: respiratory, eye, head, foot, and hand protection, may be required.
Supplying the proper hazard/chemical and exposure information for your hazard scenario is criticalin order to obtain an accurate recommendation. Inaccurate information could result in an improper recommendation. To ensure that the hazard/chemical information is accurate, consult the MSDS (Material Safety Data Sheet) supplied with the chemical. DuPont DISCLAIMS ANY RESPONSIBILITY OR LIABILITY FOR SUITS SELECTED USING these PRODUCT SELECTOR TOOLS, BASED ON ANY INCOMPLETE, INACCURATE, OR MISLEADING INFORMATION PROVIDED BY THE USER. There are other factors involved which could affect the final PPE (Personal Protective Equipment) decision and may not be considered in these Product Selector Tools. SafeSPEC™ Product Selector Tools provides information on DuPont suit styles for particular applications. The final decision on suit selection is the responsibility of the safety professional and end-user.
There are uses, environments and chemicals for which any garment will be unsuitable. It is the responsibility of the user to review available data and verify that the garment selected is appropriate for the intended use and meets all specified government and industry standards.
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 1 of 3
You may enter from one to five chemicals or other hazards that may be present in your working environment. Our tool will find the best product match for the combined hazards. Enter a single chemical or hazard if you wish to find the best possible product match for that one hazard.
Chemical or Other Hazard Name
or
CAS Number
Chemical Details | CAS | Actions |
---|
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 2 of 3
The table below shows the Normalized Breakthrough times of fabrics for the hazards selected. (Testing Details) You can find specific garments that protect against these hazards by clicking the 'Next' button below.
Done
Done
Done
TYVEK | TYCHEM | GLOVES |
---|
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
Step 3 of 3
If any of the following apply:
Please consider fire fighter PPE (personal protective equipment). Read more.
If none of these conditions apply but FR clothing is required in your working environment, close this box and proceed to the next question. Only fabrics that provide both chemical resistance to the hazards you have listed and protection during escape from a flash fire will be considered for your hazard scenario.
1 Choose Hazards
1 Enter
Chemicals
2 View Permeation Data
2 View
Data
3 View Matching Products
3 View
Products
step3of3
Hazard | Fabric/Materials | Seam | Design |
---|
Matching Products (0)
Your hazard scenario did not produce any results. May we suggest:
If you still need help, please Contact Us.
Hazard | Fabric/Materials | Seam | Design |
---|
Name | Description |
---|---|
Full Part Number | TFCHA5TOR00 |
Fabric/Materials | Tychem® F |
Design | Hooded coverall with elastics and thumb loops |
Seam | Stitched and over-taped |
Color | Orange |
Other Colors | Grey |
Sizes | MD, LG, XL, 2X, 3X, 4X, 5X |
Quantity/Box | 25 per box, individually packed. |
DuPont™ Tychem® 6000 F with socks. Hooded coverall. Attached socks and boot flap. Stitched and over-taped seams. Thumb loops. Elastication at wrists, ankles, face and waist. Self-adhesive double zipper flap and chin flap. Grey.
DuPont™ Tychem® 6000 F Gown model PL50. Wrap-over rear closure with tie. Stitched and over-taped. Grey.
DuPont™ Tychem® 6000 F Sleeve model PS32LA. Stitched and over-taped. Grey.
DuPont™ Tychem® 6000 F Apron model PA30L0. Shin-length. Neck and waist ties. Grey.
DuPont™ Tychem® 6000 F Boot cover model POBA. Fixation ties. Knee-length. Partially stitched, slip-retardant sole. Grey.
This product will be discontinued within the first half of 2024. Contact us for more details.
DuPont™ Tychem® Apron. Sleved Apron. Elasticated wrists. Adjustable FR buckles at back. Orange. DuPont™ Tychem® 6000 F Orange. Hooded coverall. Available in orange for high visibility and in sizes MD to 5X. Elasticated face, wrists, waist and ankles for an optimal fit, thumb loops prevent sleeves from riding up. Self-adhesive chin flap for tight seal of suit to face-masks.
Tychem® 6000 F garments are made from a lightweight and durable fabric (<500g per garment) consisting of a proprietary barrier film laminated to a heavy duty Tyvek® substrate. They offer excellent chemical permeation protection to an extensive range of chemicals, helping to protect personnel against numerous toxic industrial organic chemicals, highly concentrated inorganic chemicals (even under pressure), particulates, biohazards and certain chemical warfare agents.
Product Size | Article Number | Additional info |
---|---|---|
MD | D13495252 | |
LG | D13495244 | |
XL | D13495277 | |
2X | D13495222 | |
3X | D15522785 | MTO |
4X | D15522786 | MTO |
5X | D15522787 | MTO |
Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.
Property | Test Method | Typical Result | EN |
---|---|---|---|
Abrasion Resistance 7 | EN 530 Method 2 | >2000 cycles | 6/6 1 |
Basis Weight | DIN EN ISO 536 | 120 g/m2 | N/A |
Bursting Strength (Mullenburst) | ISO 2758 | 650 kPa | N/A |
Colour. | N/A (598) | Orange | N/A |
Flex Cracking Resistance 7 | EN ISO 7854 Method B | >1000 cycles | 1/6 1 |
Puncture Resistance | EN 863 | >10 N | 2/6 1 |
Resistance to water penetration | AATCC 127 | >30 kPa | N/A |
Surface Resistance at RH 25%, inside 7 | EN 1149-1 | < 2,5 • 109 Ohm | N/A |
Surface Resistance at RH 25%, outside 7 | EN 1149-1 | No antistatic treatment | N/A |
Tensile Strength (MD) | DIN EN ISO 13934-1 | >100 N | 3/6 1 |
Tensile Strength (XD) | DIN EN ISO 13934-1 | >100 N | 3/6 1 |
Thickness (PPSH-249) | DIN EN ISO 534 | 220 µm | N/A |
Trapezoidal Tear Resistance (MD) | EN ISO 9073-4 | >20 N | 2/6 1 |
Trapezoidal Tear Resistance (XD) | EN ISO 9073-4 | >20 N | 2/6 1 |
Information relating to the protective performance of a garment according to European standards where applicable. Includes important characteristics such as protection against radioactive contamination, seam strength and shelf life. Inward leakage and resistance to penetration by liquids, according to the relevant Type classification, are also detailed.
Property | Test Method | Typical Result | EN |
---|---|---|---|
Nominal protection factor 7 | EN 1073-2 | >5 | 1/3 3 |
Seam Strength | EN ISO 13935-2 | >125 N | 4/6 1 |
Shelf Life 7 | N/A (598) | 10 years 6 | N/A |
Type 3: Resistance to Penetration by Liquids (Jet Test) | EN 17491-3 | Pass | N/A |
Type 4: Resistance to Penetration by Liquids (High Level Spray Test) | EN ISO 17491-4, Method B | Pass | N/A |
Type 5: Inward Leakage of Airborne Solid Particulates | EN ISO 13982-2 | Pass | N/A |
Type 6: Resistance to Penetration by Liquids (Low Level Spray Test) | EN ISO 17491-4, Method A | Pass | N/A |
The comfort of a protective garment during use is largely determined by its weight, its permeability to vapour and air (breathability) and insulating properties. Data on these attributes is provided according to test method and, as with other data, can be compared by garment.
Property | Test Method | Typical Result | EN |
---|---|---|---|
Air Permeability (Gurley method) | ISO 5636-5 | No | N/A |
A specific test method, EN ISO 6530, is used to measure the indexes of penetration, absorption and repellency of protective clothing material exposed to liquid chemicals. Results listed here reflect the penetration resistance and repellency of DuPont fabrics to 30% sulphuric acid and 10% sodium hydroxide.
Property | Test Method | Typical Result | EN |
---|---|---|---|
Repellency to Liquids, o-Xylene | EN ISO 6530 | >95 % | 3/3 1 |
Repellency to Liquids, Butan-1-ol | EN ISO 6530 | >95 % | 3/3 1 |
Repellency to Liquids, Sodium Hydroxide (10%) | EN ISO 6530 | >95 % | 3/3 1 |
Repellency to Liquids, Sulphuric Acid (30%) | EN ISO 6530 | >95 % | 3/3 1 |
Resistance to Penetration by Liquids, Butan-1-ol | EN ISO 6530 | <1 % | 3/3 1 |
Resistance to Penetration by Liquids, Sodium Hydroxide (10%) | EN ISO 6530 | <1 % | 3/3 1 |
Resistance to Penetration by Liquids, Sulphuric Acid (30%) | EN ISO 6530 | <1 % | 3/3 1 |
Resistance to Penetration by Liquids, o-Xylene | EN ISO 6530 | <1 % | 3/3 1 |
Detailed information on the protective performance (resistance to penetration) of DuPont clothing when exposed to biologically contaminated aerosols, liquids and dusts as well as blood, body fluids and blood-borne pathogens. Sorted by relevant European standard.
Property | Test Method | Typical Result | EN |
---|---|---|---|
Resistance to Penetration by Biologically Contaminated Aerosols | ISO/DIS 22611 | log ratio >5 | 3/3 2 |
Resistance to Penetration by Blood and Body Fluids using Synthetic Blood | ISO 16603 | 20 kPa | 6/6 2 |
Resistance to Penetration by Blood-borne Pathogens using Bacteriophage Phi-X174 | ISO 16604 | 20 kPa | 6/6 2 |
Resistance to Penetration by Contaminated Liquids | EN ISO 22610 | >75 min | 6/6 2 |
Resistance to Penetration by Contaminated Solid Particles | ISO 22612 | log cfu <1 | 3/3 2 |
Permeation is the process by which a solid, liquid or gaseouses chemical moves through a protective clothing fabric at a molecular level. Permeation data assist in the selection of the most appropriate protective garment for a particular application and in the estimation of how long it can be safely worn. Standardised test methods are used to determine the resistance of DuPont materials to permeation, the results of which can be selected according to a specific chemical, chemical class or fabric.
Hazard / Chemical Name | Physical State | CAS | BT Act | BT 0.1 | BT 1.0 | EN | SSPR | MDPR | Cum 480 | Time 150 | ISO |
---|---|---|---|---|---|---|---|---|---|---|---|
2-(2-Butoxyethoxy) ethanol | Liquid | 112-34-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
2-Methyl-2-Butanol | Liquid | 75-85-4 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
2-Methyl-4-isothiazolin-3-one (20%) | Liquid | 2682-20-4 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Acetaldehyde | Liquid | 75-07-0 | imm | imm | 13*/23 | 1 | 2 | 0.06 | |||
Acetic acid (>95%) | Liquid | 64-19-7 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Acetic acid 2 ethoxy ethyl ester | Liquid | 111-15-9 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Acetic acid 2 methoxy ethyl ester | Liquid | 110-49-6 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Acetic acid ethenyl ester | Liquid | 108-05-4 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Acetic acid ethyl ester | Liquid | 141-78-6 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Acetic acid pentyl ester | Liquid | 628-63-7 | >480 | >480 | >480 | 6 | 0.007 | 0.001 | <10.2 | >480 | 6 |
Acetic anhydride | Liquid | 108-24-7 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Acetic chloride | Liquid | 75-36-5 | 155 | >480 | >480 | 6 | 0.0014 | 0.0001 | |||
Acetone | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Acetone cyanohydrin | Liquid | 75-86-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Acetonitrile | Liquid | 75-05-8 | 65*/83 | 131 | >480 | 6 | <0.4 | 0.03 | <82 | >480 | 6 |
Acetyl chloride | Liquid | 75-36-5 | 155 | >480 | >480 | 6 | 0.0014 | 0.0001 | |||
Acroleic acid | Liquid | 79-10-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Acrolein | Liquid | 107-02-8 | 51*/65 | 75*/101 | >480 | 6 | <0.5 | 0.02 | 105 | >480 | 6 |
Acrolein (10 g/m2) | Liquid | 107-02-8 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Acrylamide (50%) | Liquid | 79-06-1 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Acrylic acid | Liquid | 79-10-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Acrylic acid ethyl ester | Liquid | 140-88-5 | imm*/161 | imm*/162 | imm*/163 | <5 | 0.04 | ||||
Acrylic acid n-butyl ester | Liquid | 141-32-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | >480 | >480 | 6 |
Acrylicamide (50%) | Liquid | 79-06-1 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Acrylonitrile | Liquid | 107-13-1 | 72*/91 | 73*/92 | 103 | 3 | 8.9 | 0.0085 | |||
Acryloyl Chloride | Liquid | 814-68-6 | 166*/224 | 334 | >480 | 6 | <0.3 | 0.04 | 29.6 | >480 | 6 |
Adipic acid dinitrile | Liquid | 111-69-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Adipic acid nitrile | Liquid | 111-69-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Adiponitrile | Liquid | 111-69-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Allyl alcohol | Liquid | 107-18-6 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Allyl chloride | Liquid | 107-05-1 | 291*/400 | 381*/447 | >480 | 6 | <0.2 | 0.02 | <18.5 | >480 | 6 |
Amido sulfonic acid (15%) | Liquid | 5329-14-6 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Amino benzene | Liquid | 62-53-3 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Amino diphenyl, 4- (1 mg/ml in Methanol) | Liquid | 92-67-1 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Amino ethanol, 2- | Liquid | 141-43-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Amino ethylethanolamine | Liquid | 111-41-1 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Amino ethylethanolamine (60%) | Liquid | 111-41-1 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Amino ethylpiperazine | Liquid | 140-31-8 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Amino propane, 2- | Liquid | 75-31-0 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Ammonia (-33 °C, liquid) | Liquid | 7664-41-7 | 15 | 20 | >480 | 6 | <0.89 | 0.04 | 109 | >480 | 6 |
Ammonia (gaseous) | Vapor | 7664-41-7 | 20 | 20 | 21 | 1 | 1.5 | 0.0024 | |||
Ammonium bifluoride (sat) | Liquid | 1341-49-7 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ammonium fluoride (40%) | Liquid | 12125-01-8 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Ammonium hydrogendifluoride (sat) | Liquid | 1341-49-7 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ammonium hydroxide (32%) | Liquid | 1336-21-6 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Amyl acetate, n- | Liquid | 628-63-7 | >480 | >480 | >480 | 6 | 0.007 | 0.001 | <10.2 | >480 | 6 |
Amyl alcohol | Liquid | 71-41-0 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Amyl alcohol, tert- | Liquid | 75-85-4 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Amyl ester acetic acid | Liquid | 628-63-7 | >480 | >480 | >480 | 6 | 0.007 | 0.001 | <10.2 | >480 | 6 |
Anilin, 4-Trifluoromethoxy- | Liquid | 461-82-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Aniline | Liquid | 62-53-3 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Anthracene (sat in Toluene) | Liquid | 120-12-7 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Anthracin (sat in Toluene) | Liquid | 120-12-7 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Antimony pentachloride | Liquid | 7647-18-9 | <15 | <15 | <15 | 1 | >10 | 0.1 | |||
Arsenic (III) chloride | Liquid | 7784-34-1 | 22*/29 | 32*/38 | 59 | 2 | 334 | 0.01 | |||
Arsenic trichloride | Liquid | 7784-34-1 | 22*/29 | 32*/38 | 59 | 2 | 334 | 0.01 | |||
Azolidine | Liquid | 123-75-1 | 40*/80 | 45*/100 | 145*/185 | 4 | 4.7 | 0.05 | |||
Benzaldehyde | Liquid | 100-52-7 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Benzenamine | Liquid | 62-53-3 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Benzene | Liquid | 71-43-2 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Benzene carbonyl chloride | Liquid | 98-88-4 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Benzene sulfone chloride | Liquid | 98-09-9 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Benzene sulfonyl chloride | Liquid | 98-09-9 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Benzisothiazol 1,2- (20%) | Liquid | 2634-33-5 | >480 | >480 | >480 | 6 | <0.061 | 0.061 | <30 | >480 | 6 |
Benzo nitrile | Liquid | 100-47-0 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Benzoyl chloride | Liquid | 98-88-4 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Benzyl alcohol | Liquid | 100-51-6 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Benzyl chloride | Liquid | 100-44-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Benzyl cyanide | Liquid | 140-29-4 | >390 | >390 | >390 | 5 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Benzyl methylamine, N- | Liquid | 103-67-3 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Bis (4-(2,3-epoxypropoxy)phenyl)propane | Liquid | 1675-54-3 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Bis phenol A diglycidyl ether | Liquid | 1675-54-3 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Black Liquor (mix) | Liquid | mix | >480 | ||||||||
Boron fluoride ethyl ether | Liquid | 109-63-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Boron trifluoride diethyl etherate | Liquid | 109-63-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Boron trifluoride dimethyl etherate | Liquid | 353-42-4 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Boron trifluoride etherate | Liquid | 109-63-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Brom thiophene, 2- | Liquid | 1003-09-4 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Bromine | Liquid | 7726-95-6 | imm | imm | imm | 105 | 0.001 | ||||
Bromo 4-fluorobenzene, 1- | Liquid | 460-00-4 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Bromo fluorobenzene, 4- | Liquid | 460-00-4 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
But-3-en-2-one | Liquid | 78-94-4 | 287*/379 | >480 | >480 | 6 | <0.1 | 0.02 | <9.6 | >480 | 6 |
Butadiene, 1,3- (gaseous) | Vapor | 106-99-0 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Butanal, n- | Liquid | 123-72-8 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Butanol, 1- | Liquid | 71-36-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Butanol, n- | Liquid | 71-36-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Butanol, tert- | Liquid | 75-65-0 | 10*/147 | 37*/205 | >480 | 6 | 0.26 | 0.02 | |||
Butanone | Liquid | 78-93-3 | imm | 40*/64 | >480 | 6 | 0.36 | 0.001 | |||
Butanone oxime, 2- | Liquid | 96-29-7 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Butenal, 2- | Liquid | 123-73-9 | 121 | 147 | >480 | 6 | <1 | 0.02 | 210 | 405 | 5 |
Butoxy ethanol, 2- | Liquid | 111-76-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Butyl acetate, n- | Liquid | 123-86-4 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Butyl acrylate, n- | Liquid | 141-32-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | >480 | >480 | 6 |
Butyl alcohol, n- | Liquid | 71-36-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Butyl amine | Liquid | 109-73-9 | 170 | 200 | >480 | 6 | 0.84 | 0.01 | 137.5 | >480 | 6 |
Butyl ether, n- | Liquid | 142-96-1 | 223*/285 | 223*/285 | 224*/287 | 4 | 14.6 | 0.021 | |||
Butyl stannium trichloride | Liquid | 1118-46-3 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Butylchloroformate | Liquid | 592-34-7 | >480 | >480 | >480 | 6 | <0.07 | 0.07 | <33.6 | >480 | 6 |
Butyraldehyde, n- | Liquid | 123-72-8 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Butyric Acid | Liquid | 107-92-6 | >480 | >480 | >480 | 6 | <0.07 | 0.07 | <33.6 | >480 | 6 |
Calomel (sat) | Liquid | 10112-91-1 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Carbon disulfide | Liquid | 75-15-0 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Carbon tetrachloride | Liquid | 56-23-5 | imm | imm*/11 | >480 | 6 | 0.57 | 0.001 | |||
Carbon tetrachloride (1000 ppm) | Vapor | 56-23-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Caustic ammonia (32%) | Liquid | 1336-21-6 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Caustic soda (50% at 50 °C) | Liquid | 1310-73-2 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Caustic soda (50%) | Liquid | 1310-73-2 | >480 | >480 | >480 | 6 | <0.025 | 0.025 | <12 | >480 | 6 |
Cellosolve acetate | Liquid | 110-80-5 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Chemguard S-764P14A | Liquid | mix | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <5 | >480 | 6 |
Chlor allylene | Liquid | 107-05-1 | 291*/400 | 381*/447 | >480 | 6 | <0.2 | 0.02 | <18.5 | >480 | 6 |
Chlor trinitromethan | Liquid | 76-06-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Chlorine (gaseous) | Vapor | 7782-50-5 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Chloro 1,3-butadiene, 2- (50% in Butanol) | Liquid | 126-99-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Chloro 1-methylbenzene, 2- | Liquid | 95-49-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Chloro 2,3-epoxy propane, 1- | Liquid | 106-89-8 | 355 | 395 | >480 | 6 | <0.4 | 0.02 | 18.4 | >480 | 6 |
Chloro 2-nitrobenzene, 1- (35-40 °C, molten) | Liquid | 88-73-3 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Chloro acetic acid (80%) | Liquid | 79-11-8 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Chloro acetone (95%) | Liquid | 78-95-5 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Chloro acrylonitrile, 2- | Liquid | 920-37-6 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Chloro aniline, p- (70 °C, molten) | Liquid | 106-47-8 | imm | 11 | 1 | 256 | 0.0206 | ||||
Chloro benzenamine, 4- (70 °C, molten) | Liquid | 106-47-8 | imm | 11 | 1 | 256 | 0.0206 | ||||
Chloro benzene | Liquid | 108-90-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Chloro ethanol, 2- | Liquid | 107-07-3 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Chloro ethene | Vapor | 75-01-4 | imm | >480 | >480 | 6 | 0.02 | 0.001 | <9.6 | >480 | 6 |
Chloro methyl methyl ether | Liquid | 107-30-2 | imm*/11 | imm*/37 | >480 | 6 | 0.75 | 0.001 | |||
Chloro picrin | Liquid | 76-06-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Chloro prene, 3- | Liquid | 107-05-1 | 291*/400 | 381*/447 | >480 | 6 | <0.2 | 0.02 | <18.5 | >480 | 6 |
Chloro propan-2-one, 1- (95%) | Liquid | 78-95-5 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Chloro toluene, alpha- | Liquid | 100-44-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Chloro toluene, o- | Liquid | 95-49-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Chloroacetic ethylester | Liquid | 105-39-5 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Chloroacetic ethylester (75% in Ethanol) | Liquid | 105-39-5 | >480 | ||||||||
Chloroform | Liquid | 67-66-3 | imm | imm | imm | 10.6 | 0.001 | ||||
Chloroform (1000 ppm) | Vapor | 67-66-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Chlorsulfonic acid | Liquid | 7790-94-5 | 423 | >480 | >480 | 6 | 0.0003 | 0.0001 | |||
Chromic acid (CrO3) (44.9%) | Liquid | 1333-82-0 | >480 | >480 | >480 | 6 | <0.07 | 0.07 | <33.6 | >480 | 6 |
Citric acid (sat) | Liquid | 77-92-9 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Creosote | Liquid | 8001-58-9 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Cresol o- | Liquid | 95-48-7 | 173 | 179 | 211 | 4 | <4 | 0.02 | 674 | 295 | 5 |
Cresols, mixed isomers | Liquid | 1319-77-3 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Cresylic acid | Liquid | 1319-77-3 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Croton aldehyde | Liquid | 123-73-9 | 121 | 147 | >480 | 6 | <1 | 0.02 | 210 | 405 | 5 |
Cumene | Liquid | 98-82-8 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Cyanamide (50%) | Liquid | 420-04-2 | 62*/208 | nm | >480 | 6 | na | 0.17 | <81.6 | >480 | 6 |
Cyanobenzene | Liquid | 100-47-0 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Cyanoethylene | Liquid | 107-13-1 | 72*/91 | 73*/92 | 103 | 3 | 8.9 | 0.0085 | |||
Cyanomethane | Liquid | 75-05-8 | 65*/83 | 131 | >480 | 6 | <0.4 | 0.03 | <82 | >480 | 6 |
Cyanopropan-2-ol, 2- | Liquid | 75-86-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Cyclo hexane | Liquid | 110-82-7 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Cyclo hexanone | Liquid | 108-94-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Dahlgren Decon solution | Liquid | mix | >480 | >480 | >480 | 6 | <0.025 | 0.025 | <12 | >480 | 6 |
Diamino sulfo chloride | Liquid | 13360-57-1 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Diaminoethane, 1,2- | Liquid | 107-15-3 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Dibromoethane, 1,2- | Liquid | 106-93-4 | 84*/153 | 144*/288 | >480 | 6 | 0.52 | 0.001 | |||
Dibutyl 1,2-benzenedicarboxylate | Liquid | 84-74-2 | nm | >480 | 6 | 0.05 | |||||
Dibutyl phthalate | Liquid | 84-74-2 | nm | >480 | 6 | 0.05 | |||||
Dibutyl sebacate | Liquid | 109-43-3 | nm | >480 | 6 | <1 | 1 | ||||
Dichlorbenzen, 1,2- | Liquid | 95-50-1 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Dichlorbenzen, 1,3- | Liquid | 541-73-1 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Dichlorbenzen, 1,4- (50% in Ethanol) | Liquid | 106-46-7 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Dichlorethane, 1.2.- | Liquid | 107-06-2 | 65*/83 | 93 | 109 | 3 | <3 | 0.04 | 898 | 182 | 4 |
Dichloro -2-propanone, 1,3- (45 °C, molten) | Liquid | 534-07-6 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dichloro acetone, 1,3- (45 °C, molten) | Liquid | 534-07-6 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dichloro acetyl chloride | Liquid | 79-36-7 | 160 | 160 | 180 | 4 | 78.41 | 0.01 | |||
Dichloro ethyl ether | Liquid | 111-44-4 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dichloro ethylene, 1,1- | Liquid | 75-35-4 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dichloro methane | Liquid | 75-09-2 | imm | imm | imm | 23.7 | 0.03 | ||||
Dichloro methane (10.000 ppm) | Vapor | 75-09-2 | imm | 52 | >480 | 6 | <0.21 | 0.05 | 100 | >480 | 6 |
Dichloro methane (1000 ppm) | Vapor | 75-09-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Dichloro propene, 2,3- | Liquid | 78-88-6 | imm | imm*/25 | 54*/143 | 2 | 2.4 | 0.001 | |||
Dicyanobutane, 1,4- | Liquid | 111-69-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Diesel Fuel Grade D-2 | Liquid | mix | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Diesel fuel | Liquid | 68334-30-5 | 8*/323 | >480 | >480 | 6 | 0.02 | 0.001 | |||
Diethyl amine | Liquid | 109-89-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Diethyl benzene (95%) | Liquid | 25340-17-4 | >480 | >480 | >480 | 6 | <0.0216 | 0.0216 | <10.4 | >480 | 6 |
Diethyl ethanamine, N,N- | Liquid | 121-44-8 | >480 | >480 | >480 | 6 | 0.05 | 0.05 | <24 | >480 | 6 |
Diethyl ether | Liquid | 60-29-7 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Diethyl sulfate | Liquid | 64-67-5 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Diethylene glycol monobutyl ether | Liquid | 112-34-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Diethylene triamine | Liquid | 111-40-0 | imm | >480 | >480 | 6 | <0.01 | 0.005 | <4.8 | >480 | 6 |
Diketene Acetone (95%) | Liquid | 5394-63-8 | >480 | >480 | >480 | 6 | <0.0229 | 0.0229 | <11 | >480 | 6 |
Dimethyl acetamide, N,N- | Liquid | 127-19-5 | >480 | >480 | >480 | 6 | <0.014 | 0.014 | <6.7 | >480 | 6 |
Dimethyl amine | Vapor | 124-40-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Dimethyl aniline, N,N- | Liquid | 121-69-7 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Dimethyl dichlorosilane | Liquid | 75-78-5 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Dimethyl formamide, N,N- | Liquid | 68-12-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Dimethyl fumarate (27 °C, solid) | Solid | 624-49-7 | >480 | nm | >480 | 6 | <0.39 | 0.39 | |||
Dimethyl fumarate (37 °C, solid) | Solid | 624-49-7 | >480 | nm | >480 | 6 | <0.39 | 0.39 | |||
Dimethyl ketal | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dimethyl ketone | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dimethyl nitrosamine | Liquid | 62-75-9 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Dimethyl phenylamine, N,N- | Liquid | 121-69-7 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Dimethyl propandioate | Liquid | 108-59-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dimethyl sulfate | Liquid | 77-78-1 | >480 | >480 | >480 | 6 | <0.09 | 0.09 | <43.2 | >480 | 6 |
Dimethyl sulfide | Liquid | 75-18-3 | 83*/139 | 271 | 452 | 5 | 1.21 | 0.02 | |||
Dimethyl sulfoxide | Liquid | 67-68-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Dimethylmalonate | Vapor | 108-59-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Dioxane, 1,4- | Liquid | 123-91-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Diphenyl methane diisocyanate, 4,4'- (50 °C, molten) | Liquid | 101-68-8 | >480 | >480 | >480 | 6 | <0.0403 | 0.0403 | <19.3 | >480 | 6 |
Diphosgene | Liquid | 503-38-8 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Dowtherm Heat Transfer Fluid | Liquid | mix | >480 | >480 | >480 | 6 | <0.0267 | 0.0267 | <13 | >480 | 6 |
Dytek® A | Liquid | 15520-10-2 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Epichlorohydrin | Liquid | 106-89-8 | 355 | 395 | >480 | 6 | <0.4 | 0.02 | 18.4 | >480 | 6 |
Epoxy ethane (gaseous) | Vapor | 75-21-8 | 106 | 126 | >480 | 6 | <0.35 | 0.05 | 76 | >480 | 6 |
Epoxy propane, 1,2- | Liquid | 75-56-9 | 41 | 43 | 51 | 2 | <5 | 0.03 | 1860 | 114 | 3 |
Ethane 1,2-diol | Liquid | 107-21-1 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Ethane dioic acid (sat) | Liquid | 144-62-7 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethane diol dipropanoate, 1,2- | Liquid | 123-73-9 | 121 | 147 | >480 | 6 | <1 | 0.02 | 210 | 405 | 5 |
Ethane nitrile | Liquid | 75-05-8 | 65*/83 | 131 | >480 | 6 | <0.4 | 0.03 | <82 | >480 | 6 |
Ethane thiol | Liquid | 75-08-1 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Ethane trichloride | Liquid | 79-00-5 | 120*/173 | 164*/232 | 202*/302 | 4 | 9.1 | 0.01 | |||
Ethanol | Liquid | 64-17-5 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Ethanol amine | Liquid | 141-43-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Ethanoyl chloride | Liquid | 75-36-5 | 155 | >480 | >480 | 6 | 0.0014 | 0.0001 | |||
Ethansulphonic acid (70%) | Liquid | 594-45-6 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Ethoxy ethanol, 2- | Liquid | 110-80-5 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethoxy ethylacetat | Liquid | 111-15-9 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethyl Cellosolve® | Liquid | 110-80-5 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethyl acetate | Liquid | 141-78-6 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Ethyl acrylate | Liquid | 140-88-5 | imm*/161 | imm*/162 | imm*/163 | <5 | 0.04 | ||||
Ethyl alcohol | Liquid | 64-17-5 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Ethyl benzene | Liquid | 100-41-4 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethyl ethanamine, N- | Liquid | 109-89-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Ethyl ether | Liquid | 60-29-7 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Ethyl glycol acetate | Liquid | 111-15-9 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethyl hexanoic acid | Liquid | 149-57-5 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Ethyl mercaptan | Liquid | 75-08-1 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Ethyl nitrile | Liquid | 75-05-8 | 65*/83 | 131 | >480 | 6 | <0.4 | 0.03 | <82 | >480 | 6 |
Ethylchloroformate | Liquid | 541-41-3 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Ethylene carboxylic acid | Liquid | 79-10-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Ethylene chlorohydrin | Liquid | 107-07-3 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Ethylene diamine | Liquid | 107-15-3 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethylene dibromide | Liquid | 106-93-4 | 84*/153 | 144*/288 | >480 | 6 | 0.52 | 0.001 | |||
Ethylene dichloride | Liquid | 107-06-2 | 65*/83 | 93 | 109 | 3 | <3 | 0.04 | 898 | 182 | 4 |
Ethylene glycol | Liquid | 107-21-1 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Ethylene glycol mono ethyl ether acetate | Liquid | 111-15-9 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethylene glycol monobutyl ether | Liquid | 111-76-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Ethylene glycol monoethyl ether | Liquid | 110-80-5 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethylene glycol monomethyl ether | Liquid | 109-86-4 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethylene glycol monomethyl ether acetate | Liquid | 110-49-6 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Ethylene oxide (gaseous) | Vapor | 75-21-8 | 106 | 126 | >480 | 6 | <0.35 | 0.05 | 76 | >480 | 6 |
Ethylene tetrachloride | Liquid | 127-18-4 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Ethylene trichloride | Liquid | 79-01-6 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Ferric (II) chloride (sat) | Liquid | 7758-94-3 | >480 | >480 | >480 | 6 | <0.07 | 0.07 | <33.6 | >480 | 6 |
Ferric (III) chloride (40%) | Liquid | 7705-08-0 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Fluorobenzene | Liquid | 462-06-6 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Fluorosilicic acid (33-35%) | Liquid | 16961-83-4 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Fluorosulfonic acid | Liquid | 7789-21-1 | 87 | 194 | >480 | 6 | na | 0.02 | 29 | >480 | 6 |
Formaldehyde (37%) | Liquid | 50-00-0 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Formalin (37% (10-15% Methanol)) | Liquid | 50-00-0 | >480 | >480 | >480 | 6 | <0.0048 | 0.0048 | <2.3 | >480 | 6 |
Formalin (37%) | Liquid | 50-00-0 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Formic acid (50%) | Liquid | 64-18-6 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Formic acid (>95%) | Liquid | 64-18-6 | 172 | 260 | >480 | 6 | 0.24 | 0.001 | |||
Furaldehyde, 2- | Liquid | 98-01-1 | 459 | >480 | >480 | 6 | na | 0.03 | <14.4 | >480 | 6 |
Furan | Liquid | 110-00-9 | 75 | 97 | >480 | 6 | <1 | 0.02 | 206 | 411 | 5 |
Furfural | Liquid | 98-01-1 | 459 | >480 | >480 | 6 | na | 0.03 | <14.4 | >480 | 6 |
Gasoline, leaded | Liquid | mix | imm | imm*/21 | 0.32 | 0.001 | |||||
Gasoline, unleaded | Liquid | 86290-81-5 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Glutaral (50%) | Liquid | 111-30-8 | 150 | 170 | 200 | 4 | 1.861 | 0.01 | |||
Glutaraldehyde (50%) | Liquid | 111-30-8 | 150 | 170 | 200 | 4 | 1.861 | 0.01 | |||
Glycol alcohol | Liquid | 107-21-1 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Glycol chlorohydrin | Liquid | 107-07-3 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Green Liquor (mix) | Liquid | mix | >480 | ||||||||
Heptane | Liquid | 142-82-5 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Hexamethylene diamine (45 °C, molten) | Liquid | 124-09-4 | 423 | >480 | >480 | 6 | 0.003 | 0.0001 | <1.4 | >480 | 6 |
Hexamethylene diisocyanate | Liquid | 822-06-0 | >480 | >480 | >480 | 6 | <0.0271 | 0.0271 | <13 | >480 | 6 |
Hexane, n- | Liquid | 110-54-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Hexanone | Liquid | 108-94-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Hexone | Liquid | 108-10-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Hexyl chloro formate, 2- | Liquid | 6092-54-2 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Hydrazine | Liquid | 302-01-2 | 269 | 283 | 352 | 5 | 2.3 | 0.001 | |||
Hydriodic acid (55-57%) | Liquid | 10034-85-2 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Hydrobromic acid (48%) | Liquid | 10035-10-6 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Hydrochloric acid (37%) | Liquid | 7647-01-0 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Hydrofluoric acid (48-51%) | Liquid | 7664-39-3 | >480 | >480 | >480 | 6 | <0.025 | 0.025 | <12 | >480 | 6 |
Hydrofluoric acid (60%) | Liquid | 7664-39-3 | 18 | 52 | 373 | 5 | na | 0.005 | |||
Hydrofluoric acid (70%) | Liquid | 7664-39-3 | 22 | 35 | 293 | 5 | na | 0.005 | 414 | 227 | 4 |
Hydrogen bromide (gaseous) | Vapor | 10035-10-6 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Hydrogen chloride (gaseous) | Vapor | 7647-01-0 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Hydrogen fluoride (20-27 °C, gaseous) | Vapor | 7664-39-3 | imm | imm | 23 | 1 | na | 0.05 | |||
Hydrogen peroxide (50%) | Liquid | 7722-84-1 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Hydrogen peroxide (70%) | Liquid | 7722-84-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Hydroxy 1,2,3-propanetricarboxylic acid, 2- (sat) | Liquid | 77-92-9 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Hydroxy 1-ethanethiol, 2- | Liquid | 60-24-2 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Hydroxy 2-methylpropionitrile, 2- | Liquid | 75-86-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Hydroxy isobutyronitrile | Liquid | 75-86-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Hydroxy toluene | Liquid | 100-51-6 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Hydroxy toluene, o- | Liquid | 95-48-7 | 173 | 179 | 211 | 4 | <4 | 0.02 | 674 | 295 | 5 |
Hypophosphorus acid (50%) | Liquid | 6303-21-5 | >480 | >480 | >480 | 6 | <0.09 | 0.09 | <43.2 | >480 | 6 |
Iodomethane | Liquid | 74-88-4 | 254 | 296 | >480 | 6 | na | 0.07 | 53.6 | >480 | 6 |
Isobutyl methyl ketone | Liquid | 108-10-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Isophthaloyldichloride (45 °C, molten) | Liquid | 99-63-8 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Isopropanol | Liquid | 67-63-0 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Isopropyl alcohol | Liquid | 67-63-0 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Isopropyl amine | Liquid | 75-31-0 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Isopropyl benzene | Liquid | 98-82-8 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Isopropyl bromoacetate (>95%) | Liquid | 29921-57-1 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Isopropylidenediphenol diglycidyl ether, 4,4'- | Liquid | 1675-54-3 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Kerosene | Liquid | 8008-20-6 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Ketone propane | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Lewisite (L), FINABEL 0.7.C | Liquid | 541-25-3 | >1558 | >1558 | |||||||
Lewisite (L), MIL-STD-282 (100 g/m2) | Liquid | 541-25-3 | 3608 | ||||||||
Limonene d- | Liquid | 5989-27-5 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Maleic anhydride (66 °C, molten) | Liquid | 108-31-6 | 21 | 22 | 24 | 1 | 24.6 | 0.016 | |||
Mercapto acetic acid | Liquid | 68-11-1 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Mercapto ethanol | Liquid | 60-24-2 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Mercuric I chloride (sat) | Liquid | 10112-91-1 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Mercury | Liquid | 7439-97-6 | >480 | >480 | >480 | 6 | <0.09 | 0.09 | <43.2 | >480 | 6 |
Methacrylic acid | Liquid | 79-41-4 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Methanesulfonyl chloride | Liquid | 124-63-0 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Methanesulphonic acid | Liquid | 75-75-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methanethiol | Vapor | 74-93-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methanol | Liquid | 67-56-1 | 56 | 117 | >480 | 6 | 0.14 | 0.02 | |||
Methoxy 2-methylpropane, 2- | Liquid | 1634-04-4 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Methoxy chloromethane | Liquid | 107-30-2 | imm*/11 | imm*/37 | >480 | 6 | 0.75 | 0.001 | |||
Methoxy ethanol, 2 | Liquid | 109-86-4 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Methoxy ethylacetate, 2- | Liquid | 110-49-6 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Methyl -2-pyridyl acetate | Liquid | 1658-42-0 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methyl 1,5-pentantedinitrile, 2- | Liquid | 4553-62-2 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Methyl 2-methyl-2-propenoate | Liquid | 80-62-6 | imm*/26 | imm*/53 | 1.4 | 0.001 | |||||
Methyl 2-pyrrolidon, N- | Liquid | 872-50-4 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Methyl 4-isopropenyl-1-cyclohexene, 1- | Liquid | 5989-27-5 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Methyl Ethyl Ketone Peroxide (35%) | Liquid | 1338-23-4 | >480 | >480 | >480 | 6 | <0.018 | 0.018 | <10 | >480 | 6 |
Methyl N-nitrosomethanamine, N- | Liquid | 62-75-9 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Methyl acetyl | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Methyl acrolein | Liquid | 123-73-9 | 121 | 147 | >480 | 6 | <1 | 0.02 | 210 | 405 | 5 |
Methyl acrylate | Liquid | 96-33-3 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Methyl amine (gaseous) | Vapor | 74-89-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methyl aniline, o- | Liquid | 95-53-4 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Methyl benzol | Liquid | 108-88-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methyl benzylamine, N- | Liquid | 103-67-3 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Methyl chloride (gaseous) | Vapor | 74-87-3 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Methyl chloro formate | Liquid | 79-22-1 | 99*/175 | 204*/308 | >480 | 6 | 0.17 | 0.05 | <24 | >480 | 6 |
Methyl cyanide | Liquid | 75-05-8 | 65*/83 | 131 | >480 | 6 | <0.4 | 0.03 | <82 | >480 | 6 |
Methyl ethyl ketone | Liquid | 78-93-3 | imm | 40*/64 | >480 | 6 | 0.36 | 0.001 | |||
Methyl ethyl ketoxime | Liquid | 96-29-7 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Methyl formamide, N- | Liquid | 123-39-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methyl hydrazine | Liquid | 60-34-4 | 83*/206 | 183*/283 | 280*/413 | 5 | 0.98 | 0.01 | |||
Methyl imidazole, 1- | Liquid | 616-47-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Methyl iodide | Liquid | 74-88-4 | 254 | 296 | >480 | 6 | na | 0.07 | 53.6 | >480 | 6 |
Methyl isocyanate | Liquid | 624-83-9 | imm | imm | 0.42 | 0.001 | |||||
Methyl ketone | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Methyl mercaptan | Vapor | 74-93-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methyl methacrylate | Liquid | 80-62-6 | imm*/26 | imm*/53 | 1.4 | 0.001 | |||||
Methyl pentan-2-one, 4- | Liquid | 108-10-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methyl phenols | Liquid | 1319-77-3 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Methyl propan-2-ol, 2- | Liquid | 75-65-0 | 10*/147 | 37*/205 | >480 | 6 | 0.26 | 0.02 | |||
Methyl propenoic acid, 2- | Liquid | 79-41-4 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Methyl pyridine, 2- | Liquid | 109-06-8 | >480 | >480 | >480 | 6 | <0.024 | 0.024 | <11.5 | >480 | 6 |
Methyl pyridine, 3- | Liquid | 108-99-6 | >480 | >480 | >480 | 6 | <0.024 | 0.024 | <11.5 | >480 | 6 |
Methyl tert-butyl ether | Liquid | 1634-04-4 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Methyl trichlorosilane | Liquid | 75-79-6 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Methyl vinyl ketone | Liquid | 78-94-4 | 287*/379 | >480 | >480 | 6 | <0.1 | 0.02 | <9.6 | >480 | 6 |
Methylen Isocyclohexylamine, 4,4- (40 °C) | Liquid | 1761-71-3 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Methylene bromide | Liquid | 74-95-3 | imm | imm | 20 | 1 | 111 | 0.05 | |||
Methylene chloride | Liquid | 75-09-2 | imm | imm | imm | 23.7 | 0.03 | ||||
Methylene chloride (10.000 ppm) | Vapor | 75-09-2 | imm | 52 | >480 | 6 | <0.21 | 0.05 | 100 | >480 | 6 |
Methylene chloride (1000 ppm) | Vapor | 75-09-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Methylene diphenyl diisocyanate, 4,4'- (50 °C, molten) | Liquid | 101-68-8 | >480 | >480 | >480 | 6 | <0.0403 | 0.0403 | <19.3 | >480 | 6 |
Naphthalene | Solid | 91-20-3 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Naphthalene (25% in Diethylene glycol dimethylether) | Liquid | 91-20-3 | >480 | >480 | >480 | 6 | <0.007 | 0.007 | <3.4 | >480 | 6 |
Neoprene (50% in Butanol) | Liquid | 126-99-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Nicotine | Liquid | 54-11-5 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Nitric acid (70%) | Liquid | 7697-37-2 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Nitric acid (>95%) | Liquid | 7697-37-2 | 14*/19 | 46 | 65*/82 | 3 | <8 | <0.03 | 34/90 min | 134 | 4 |
Nitric acid, red fuming (90%) | Liquid | 52583-42-3 | imm | imm*/10 | 32 | 2 | na | 0.08 | 342/80 min | 59 | 2 |
Nitro benzene | Liquid | 98-95-3 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Nitro chlormethan | Liquid | 76-06-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Nitro methane | Liquid | 75-52-5 | 157 | 233 | 0.97 | 0.001 | |||||
Nitro propane, 2- | Liquid | 79-46-9 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Nitro toluene, 2- | Liquid | 88-72-2 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Nitrogen dioxide | Vapor | 10102-44-0 | <15 | <15 | >0.2 | 0.01 | |||||
Norflurane | Vapor | 811-97-2 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Octyl chlor formiate | Liquid | 7452-59-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Oleum (20% free SO3) | Liquid | 8014-95-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Oleum (40% free SO3) | Liquid | 8014-95-7 | 130*/220 | 455*/468 | >480 | 6 | 0.32 | 0.0001 | |||
Oleum (65% free SO3) | Liquid | 8014-95-7 | 180 | 248 | 370 | 5 | na | 0.04 | 398 | 428 | 5 |
Oxalic acid (sat) | Liquid | 144-62-7 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
PCB in transformer oil (mix) | Liquid | mix | 324*/428 | >480 | >480 | 6 | 0.032 | 0.01 | |||
Pentachloroantimony | Liquid | 7647-18-9 | <15 | <15 | <15 | 1 | >10 | 0.1 | |||
Pentanedial, 1,5- (50%) | Liquid | 111-30-8 | 150 | 170 | 200 | 4 | 1.861 | 0.01 | |||
Pentanoic acid | Liquid | 109-52-4 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Pentanol, 1- | Liquid | 71-41-0 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Pentanol, tert- | Liquid | 75-85-4 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Pentene nitrile, 2- | Liquid | 13284-42-9 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Pentyl acetate | Liquid | 628-63-7 | >480 | >480 | >480 | 6 | 0.007 | 0.001 | <10.2 | >480 | 6 |
Peracetic Acid (32%) | Liquid | 79-21-0 | >480 | >480 | >480 | 6 | <0.0123 | 0.0123 | <6 | >480 | 6 |
Perchloric acid (70%) | Liquid | 7601-90-3 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Phenethylene | Liquid | 100-42-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Phenol (45 °C, molten) | Liquid | 108-95-2 | 22 | 25 | 29 | 1 | na | 0.05 | >355, 120 min | 56 | 2 |
Phenol (60 °C, molten) | Liquid | 108-95-2 | imm | imm | imm | na | 0.01 | 426/24 min | 14 | 1 | |
Phenol (85%) | Liquid | 108-95-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Phenyl acetonitrile | Liquid | 140-29-4 | >390 | >390 | >390 | 5 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Phenyl amine | Liquid | 62-53-3 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Phenyl chlor formiate | Liquid | 1885-14-9 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Phenyl chloride | Liquid | 108-90-7 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Phenyl cyanide | Liquid | 100-47-0 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Phenyl ethane | Liquid | 100-41-4 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Phenyl ethanol, 1- | Liquid | 98-85-1 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Phenyl propane, 2- | Liquid | 98-82-8 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Phenyl trichlorosilane | Liquid | 98-13-5 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Phosgene | Vapor | 75-44-5 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Phosphine | Vapor | 7803-51-2 | imm | imm | >0.11 | 0.003 | |||||
Phosphinic acid (50%) | Liquid | 6303-21-5 | >480 | >480 | >480 | 6 | <0.09 | 0.09 | <43.2 | >480 | 6 |
Phosphoric acid (85%) | Liquid | 7664-38-2 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Phosphorus oxychloride | Liquid | 10025-87-3 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 | |
Phosphorus trichloride | Liquid | 7719-12-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Picoline, 2- | Liquid | 109-06-8 | >480 | >480 | >480 | 6 | <0.024 | 0.024 | <11.5 | >480 | 6 |
Picoline, 3- | Liquid | 108-99-6 | >480 | >480 | >480 | 6 | <0.024 | 0.024 | <11.5 | >480 | 6 |
Pimelic ketone | Liquid | 108-94-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Polymethylene polyphenyle isocyanate (p-MDI) | Liquid | 9016-87-9 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Potassium acetate (sat) | Liquid | 127-08-2 | >480 | >480 | >480 | 6 | <0.07 | 0.07 | <33.6 | >480 | 6 |
Potassium chromate (sat) | Liquid | 7789-00-6 | >480 | >480 | >480 | 6 | <0.08 | 0.08 | <38.4 | >480 | 6 |
Potassium hydroxide (45%) | Liquid | 1310-58-3 | >480 | >480 | >480 | 6 | <0.023 | 0.023 | <11 | >480 | 0 |
Potassium hydroxide (50%) | Liquid | 1310-58-3 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Prop-2-en-1-al | Liquid | 107-02-8 | 51*/65 | 75*/101 | >480 | 6 | <0.5 | 0.02 | 105 | >480 | 6 |
Prop-2-en-1-al (10 g/m2) | Liquid | 107-02-8 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Prop-2-yn-1-ol | Liquid | 107-19-7 | 123 | 123 | 127 | 4 | 37.9 | 0.07 | |||
Propan -1-ol | Liquid | 71-23-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Propan -2-ol | Liquid | 67-63-0 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Propan -2-one | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Propanoic acid | Liquid | 79-09-4 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Propanol, 1- | Liquid | 71-23-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Propanol, n- | Liquid | 71-23-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Propargyl alcohol | Liquid | 107-19-7 | 123 | 123 | 127 | 4 | 37.9 | 0.07 | |||
Propen 1-ol, 2- | Liquid | 107-18-6 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Propenamide (50%) | Liquid | 79-06-1 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Propene acid | Liquid | 79-10-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Propenenitrile, 2- | Liquid | 107-13-1 | 72*/91 | 73*/92 | 103 | 3 | 8.9 | 0.0085 | |||
Propenoic acid butyl ester, 2- | Liquid | 141-32-2 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | >480 | >480 | 6 |
Propenoic acid nitrile | Liquid | 107-13-1 | 72*/91 | 73*/92 | 103 | 3 | 8.9 | 0.0085 | |||
Propychloroformate | Liquid | 109-61-5 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Propyl alcohol | Liquid | 71-23-8 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Propyl amine, n- | Liquid | 107-10-8 | imm | 16*/21 | >480 | 6 | 0.52 | 0.05 | |||
Propyl bromide, n- | Liquid | 106-94-5 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Propylene aldehyde | Liquid | 123-73-9 | 121 | 147 | >480 | 6 | <1 | 0.02 | 210 | 405 | 5 |
Propylene oxide, 1,2- | Liquid | 75-56-9 | 41 | 43 | 51 | 2 | <5 | 0.03 | 1860 | 114 | 3 |
Pyridene, 2-fluoro-6-(trifluoromethyl) | Liquid | 94239-04-0 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Pyridine | Liquid | 110-86-1 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Pyroacetic ether | Liquid | 67-64-1 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Pyrrolidine | Liquid | 123-75-1 | 40*/80 | 45*/100 | 145*/185 | 4 | 4.7 | 0.05 | |||
Sarin (GB), FINABEL 0.7.C | Liquid | 107-44-8 | >14008 | ||||||||
Sarin (GB), MIL-STD-282 (100 g/m2) | Liquid | 107-44-8 | >4808 | ||||||||
Silane | Vapor | 7803-62-5 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Silicon tetrachloride | Liquid | 10026-04-7 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Sodium bisulphite (38-40%) | Liquid | 7631-90-5 | >480 | >480 | >480 | 6 | <0.07 | 0.07 | <33.6 | >480 | 6 |
Sodium cyanide (45%) | Liquid | 143-33-9 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Sodium cyanide (sat) | Liquid | 143-33-9 | >480 | >480 | >480 | 6 | <0.07 | 0.07 | <33.6 | >480 | 6 |
Sodium hydroxide (50% at 50 °C) | Liquid | 1310-73-2 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Sodium hydroxide (50%) | Liquid | 1310-73-2 | >480 | >480 | >480 | 6 | <0.025 | 0.025 | <12 | >480 | 6 |
Sodium hypochlorite (15%) | Liquid | 7681-52-9 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Soman (GD), FINABEL 0.7.C | Liquid | 96-64-0 | >14008 | ||||||||
Soman (GD), MIL-STD-282 (100 g/m2) | Liquid | 96-64-0 | >4808 | ||||||||
Spiritus | Liquid | 64-17-5 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Styrene | Liquid | 100-42-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Sulfamic acid (15%) | Liquid | 5329-14-6 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Sulfamidic acid (15%) | Liquid | 5329-14-6 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Sulfur Mustard (HD), FINABEL 0.7.C | Liquid | 505-60-2 | >14008 | ||||||||
Sulfur Mustard (HD), MIL-STD-282 (100 g/m2) | Liquid | 505-60-2 | >4808 | ||||||||
Sulfur dioxide | Vapor | 7446-09-5 | 28*/46 | 28*/46 | >480 | 6 | <0.5 | 0.1 | <94 | >480 | 6 |
Sulfuric acid (98% at 50 °C) | Liquid | 7664-93-9 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Sulfuric acid (>95%) | Liquid | 7664-93-9 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Sulfuric acid diethyl ester | Liquid | 64-67-5 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Sulfuric acid dimethyl ester | Liquid | 77-78-1 | >480 | >480 | >480 | 6 | <0.09 | 0.09 | <43.2 | >480 | 6 |
Sulfuric acid fuming (20% free SO3) | Liquid | 8014-95-7 | >480 | >480 | >480 | 6 | <0.06 | 0.06 | <28.8 | >480 | 6 |
Sulfuric acid fuming (40% free SO3) | Liquid | 8014-95-7 | 130*/220 | 455*/468 | >480 | 6 | 0.32 | 0.0001 | |||
Sulfuric acid fuming (65% free SO3) | Liquid | 8014-95-7 | 180 | 248 | 370 | 5 | na | 0.04 | 398 | 428 | 5 |
Sulfuryl chloride | Liquid | 7791-25-5 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Tabun (GA), FINABEL 0.7.C | Liquid | 77-81-6 | >14008 | ||||||||
Tabun (GA), MIL-STD-282 (100 g/m2) | Liquid | 77-81-6 | >4808 | ||||||||
Tetrachloro bisphenol-A, 2,2',6,6'- | Solid | 79-95-8 | >480 | >480 | >480 | 6 | <0.1 | 0.1 | <48 | >480 | 6 |
Tetrachloro ethane, 1,1,2,2,- | Liquid | 79-34-5 | >480 | >480 | >480 | 6 | <0.008 | 0.008 | <3.8 | >480 | 6 |
Tetrachloro ethylene, 1,1,2,2- | Liquid | 127-18-4 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Tetrachloro methane | Liquid | 56-23-5 | imm | imm*/11 | >480 | 6 | 0.57 | 0.001 | |||
Tetrachloro methane (1000 ppm) | Vapor | 56-23-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Tetraethylene pentamine | Liquid | 112-57-2 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Tetrafluoroethane, 1,1,1,2- | Vapor | 811-97-2 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Tetrahydrofuran | Liquid | 109-99-9 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Tetramethyl ammonium hydroxide (25%) | Liquid | 75-59-2 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Thiazol, 1,3- | Liquid | 288-47-1 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Thioalkohol | Liquid | 75-08-1 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Thioglycolic acid | Liquid | 68-11-1 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Thionyl chloride | Liquid | 7719-09-7 | 21 | 21 | 33 | 2 | nm | 0.1 | nm | 47 | 2 |
Thiophene | Liquid | 110-02-1 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Tin chloride, mono-n-butyl | Liquid | 1118-46-3 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Tin chloride, tri-n-butyl | Liquid | 1461-22-9 | nm | >480 | 6 | nm | 0.2 | ||||
Titan(IV) chloride | Liquid | 7550-45-0 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Titanium tetrachloride | Liquid | 7550-45-0 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Toluene | Liquid | 108-88-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Toluene diisocyanate, 2,4- | Liquid | 584-84-9 | >480 | >480 | >480 | 6 | <0.0281 | 0.0281 | <13.5 | >480 | 6 |
Toluene diisocyanate, 2,4- (80%) | Liquid | 584-84-9 | >480 | >480 | >480 | 6 | <0.0281 | 0.0281 | <13.5 | >480 | 6 |
Toluidine, o- | Liquid | 95-53-4 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Tributyl amine (95%) | Liquid | 102-82-9 | >480 | >480 | >480 | 6 | <0.04 | 0.04 | <19.2 | >480 | 6 |
Trichloro acetic acid (sat) | Liquid | 76-03-9 | >480 | >480 | >480 | 6 | <0.03 | 0.03 | <14.4 | >480 | 6 |
Trichloro acetone, 1,1,3- (87.7%) | Liquid | 921-03-9 | 431*/458 | 467*/476 | >480 | 6 | <0.2 | 0.05 | <24 | >480 | 6 |
Trichloro benzene, 1,2,4- | Liquid | 120-82-1 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Trichloro ethane, 1,1,2- | Liquid | 79-00-5 | 120*/173 | 164*/232 | 202*/302 | 4 | 9.1 | 0.01 | |||
Trichloro ethanol, 2,2,2- | Liquid | 115-20-8 | >480 | >480 | >480 | 6 | <0.008 | 0.008 | <3.8 | >480 | 6 |
Trichloro ethylene | Liquid | 79-01-6 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Trichloro methane | Liquid | 67-66-3 | imm | imm | imm | 10.6 | 0.001 | ||||
Trichloro methane (1000 ppm) | Vapor | 67-66-3 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Trichloro phenylsilane | Liquid | 98-13-5 | >480 | >480 | >480 | 6 | <0.0001 | 0.0001 | <0.04 | >480 | 6 |
Triethyl amine | Liquid | 121-44-8 | >480 | >480 | >480 | 6 | 0.05 | 0.05 | <24 | >480 | 6 |
Triethylentetramine (60%) | Liquid | 112-24-3 | >480 | >480 | >480 | 6 | <0.005 | 0.005 | <2.4 | >480 | 6 |
Trifluoro acetic acid | Liquid | 76-05-1 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Trifluoro methansulfonic acid | Liquid | 1493-13-6 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Trimethyl chinon (30 °C, molten) | Liquid | 935-92-2 | nm | >480 | 6 | nm | 0.05 | ||||
VX Nerve Agent, FINABEL 0.7.C | Liquid | 50782-69-9 | >14008 | ||||||||
VX Nerve Agent, MIL-STD-282 (100 g/m2) | Liquid | 50782-69-9 | >4808 | ||||||||
Vinyl acetate | Liquid | 108-05-4 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Vinyl benzol | Liquid | 100-42-5 | >480 | >480 | >480 | 6 | <0.05 | 0.05 | <24 | >480 | 6 |
Vinyl carbinol | Liquid | 107-18-6 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Vinyl chloride | Vapor | 75-01-4 | imm | >480 | >480 | 6 | 0.02 | 0.001 | <9.6 | >480 | 6 |
Vinyl cyanide | Liquid | 107-13-1 | 72*/91 | 73*/92 | 103 | 3 | 8.9 | 0.0085 | |||
Vinyl ethylene (gaseous) | Vapor | 106-99-0 | >480 | >480 | >480 | 6 | <0.01 | 0.01 | <4.8 | >480 | 6 |
Vinylidene chloride | Liquid | 75-35-4 | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
White Liquor | Liquid | mix | >480 | ||||||||
White spirit | Liquid | mix | >480 | >480 | >480 | 6 | <0.02 | 0.02 | <9.6 | >480 | 6 |
Xylene, mixed isomers | Liquid | 1330-20-7 | >480 | >480 | >480 | 6 | <0.001 | 0.001 | <0.48 | >480 | 6 |
Xylidine, 2,4- | Liquid | 95-68-1 | >480 | >480 | >480 | 6 | <0.0195 | 0.0195 | <9.4 | >480 | 6 |